{"id":2151,"date":"2014-08-27T22:25:38","date_gmt":"2014-08-28T01:25:38","guid":{"rendered":"https:\/\/kyaserv.com.ar\/web\/?p=2151"},"modified":"2014-08-27T23:13:14","modified_gmt":"2014-08-28T02:13:14","slug":"celdas-de-carga-cardinal","status":"publish","type":"post","link":"https:\/\/kyaserv.com.ar\/web\/celdas-de-carga-cardinal\/","title":{"rendered":"Celdas de Carga Cardinal"},"content":{"rendered":"<p><img loading=\"lazy\" class=\"aligncenter wp-image-2154 size-medium\" src=\"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/Cardinal_Scale_Logo-300x90.jpg\" alt=\"Cardinal_Scale_Logo\" width=\"300\" height=\"90\" srcset=\"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/Cardinal_Scale_Logo-300x90.jpg 300w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/Cardinal_Scale_Logo-182x55.jpg 182w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/Cardinal_Scale_Logo-200x60.jpg 200w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/Cardinal_Scale_Logo-340x102.jpg 340w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/Cardinal_Scale_Logo.jpg 462w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><img loading=\"lazy\" class=\"aligncenter wp-image-2155 size-medium\" src=\"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/sca-50-cardinal-231x300.jpg\" alt=\"sca-50-cardinal\" width=\"231\" height=\"300\" srcset=\"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/sca-50-cardinal-231x300.jpg 231w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/sca-50-cardinal-42x55.jpg 42w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/sca-50-cardinal-340x440.jpg 340w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/sca-50-cardinal.jpg 360w\" sizes=\"(max-width: 231px) 100vw, 231px\" \/><\/p>\n<h2 style=\"font-weight: bold; color: #3d3d3d; text-align: center;\"><\/h2>\n<h2>Serie SCA<\/h2>\n<h2><strong>Celdas de carga an\u00e1logas tipo compresi\u00f3n<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<p><strong>Capacidades:<\/strong><\/p>\n<ul>\n<li><b>Mod. 50K-SCA de 50,000lb \/\u00a0<\/b><strong>22680kg.<\/strong><\/li>\n<li><strong>Mod. 100K-SCA de 100,000lb \/45,360kg<\/strong><\/li>\n<li><b>Mod. 120K-SCA de 120,000lb\/\u00a0<\/b><strong>54,430kg<\/strong><\/li>\n<\/ul>\n<p><strong>Sellada herm\u00e9ticamente\u00a0 (IP68)<\/strong><\/p>\n<p><strong>Fabricada de acero inoxidable<\/strong><\/p>\n<p style=\"text-align: justify;\"><strong>Cable de 10m integrado<\/strong><\/p>\n<p style=\"text-align: justify;\">Las celdas de carga para compresi\u00f3n de alta capacidad son ideales para aplicaciones con celdas m\u00faltiples, como en las balanzas para camiones y sistemas para tanques de alta capacidad.<\/p>\n<p style=\"text-align: justify;\">Estas celdas est\u00e1n disponibles en capacidades de 22680kg, 45,360kg y 54,430kg.<\/p>\n<p style=\"text-align: justify;\">Las celdas de carga son fabricadas de acero inoxidable con la finalidad de ofrecer la m\u00e1xima protecci\u00f3n en ambientes con\u00a0 agentes c\u00e1usticos, corrosivos y humedad. Las celdas est\u00e1n herm\u00e9ticamente blindadas contra el ingreso de agua (IP68)<\/p>\n<p style=\"text-align: justify;\">Las celdas se proveen con botones receptores de carga en ambos extremos y cable multi-conductor integrado de 9m, sellado herm\u00e9ticamente.<\/p>\n<p style=\"text-align: justify;\">\n<p style=\"text-align: justify;\"><strong style=\"color: #000000;\">ESPECIFICACIONES<\/strong><strong style=\"color: #000000;\">\u00a0<\/strong><strong style=\"color: #000000;\">Informaci\u00f3n Mec\u00e1nica<\/strong><\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Capacidad nominal (C.N.) E<sub>max<\/sub>: \u00a022680, 45360 &amp; 54430kg<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Carga muerta m\u00ednima: 226kg \/ 454kg \/ 544kg<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Sobrecarga de seguridad: 150%\u00a0 C.N.<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Sobrecarga l\u00edmite: 300% C.N.<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Deflexi\u00f3n a C.N. : 0.33mm<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Material del elemento de resorte: 17-4 PH<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Peso Neto: 50K-SCA: 5.8kg \/ 100K-SCA: 4.8kg \/ 120K-SCA: 5kg<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\"><strong>Informaci\u00f3n el\u00e9ctrica\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/strong><\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Se\u00f1al de salida nominal\u00a0: 2mv\/V<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Voltaje de excitaci\u00f3n (recomendado): 10VDC<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Voltaje de excitaci\u00f3n (m\u00e1ximo): 15VDC<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Largo del cable: 10m<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Resistencia excitaci\u00f3n:\u00a01150\u00b160 ohmios<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Resistencia se\u00f1al:\u00a01050\u00b115ohmios<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Salida en cero: &gt;2% Cap. Nom.<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Resistencia de aislamiento:\u00a0&gt;5000 mega ohmios a 50VDC<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\"><strong>Certificaciones<\/strong><\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\"><strong>Entidad\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 NTEP\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 OIML<\/strong><\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Certificado No\u00a0\u00a0\u00a0\u00a089-042A4\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 R60\/1991-DK-97.04 rev.1<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Clase de precisi\u00f3n: \u00a0IIIL\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0C3<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">No m\u00e1x.div-\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 10000\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 3000<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Simple \/ M\u00faltiple\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0M<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">S\u00edmbolo de humedad:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0CH<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Divisi\u00f3n m\u00ednima de verificaci\u00f3n:<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">0.68\/1.36\/1.63kg\u00a0\u00a0 0.45\/0.9\/1.09kg<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\"><strong>Informaci\u00f3n ambiental<\/strong><\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Rango temperatura de compensaci\u00f3n\u00a0-10\u00b0C a +40\u00b0C<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Rango temperatura de operaci\u00f3n: -29\u00b0C a + 93\u00b0C<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">C\u00f3digo de construcci\u00f3n &amp; protecci\u00f3n: CP-67 HU, IP68<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Efecto de presi\u00f3n barom\u00e9trica en la salida de se\u00f1al con carga cero: &lt;1 v (min) 1kPa<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\"><strong>C\u00f3digos\u00a0 de color<\/strong><\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">+ Excitaci\u00f3n\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 verde<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">&#8211; Excitaci\u00f3n\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 negro<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">&#8211; Se\u00f1al\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0blanco<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">+ Se\u00f1al\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0rojo<\/p>\n<p style=\"color: rgb(0, 0, 0); text-align: justify;\">Tierra (blindaje)\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 amarillo<\/p>\n<p style=\"text-align: justify;\">\n<p style=\"text-align: justify;\"><a href=\"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/cardinal_sca50.pdf\" target=\"_blank\">DESCARGAR FOLLETO<\/a><\/p>\n<p style=\"text-align: justify;\">\n<figure id=\"attachment_2157\" aria-describedby=\"caption-attachment-2157\" style=\"width: 320px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" class=\"wp-image-2157 size-full\" src=\"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/instalacion-celda-cardinal.jpg\" alt=\"instalacion celda cardinal\" width=\"320\" height=\"256\" srcset=\"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/instalacion-celda-cardinal.jpg 320w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/instalacion-celda-cardinal-300x240.jpg 300w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/instalacion-celda-cardinal-68x55.jpg 68w, https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/instalacion-celda-cardinal-200x160.jpg 200w\" sizes=\"(max-width: 320px) 100vw, 320px\" \/><figcaption id=\"caption-attachment-2157\" class=\"wp-caption-text\">Instalaci\u00f3n de Celda de carga CARDINAL (USA) Mod. SCA en balanza para camiones<\/figcaption><\/figure>\n<figure id=\"attachment_2156\" aria-describedby=\"caption-attachment-2156\" style=\"width: 333px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" class=\"wp-image-2156 size-full\" src=\"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/cardinal_50ksca_dimensiones.gif\" alt=\"cardinal_50ksca_dimensiones\" width=\"333\" height=\"324\" \/><figcaption id=\"caption-attachment-2156\" class=\"wp-caption-text\">Medidas celda SCA<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Serie SCA Celdas de carga an\u00e1logas tipo compresi\u00f3n &nbsp; Capacidades: Mod. 50K-SCA de 50,000lb \/\u00a022680kg. Mod. 100K-SCA de 100,000lb \/45,360kg Mod. 120K-SCA de 120,000lb\/\u00a054,430kg Sellada herm\u00e9ticamente\u00a0 (IP68) Fabricada de acero inoxidable Cable de 10m integrado Las celdas de carga para compresi\u00f3n de alta capacidad son ideales para aplicaciones con celdas [\u2026] <\/p>\n<div class=\"clear\"><\/div>\n<p><a class=\"more_link clearfix\" href=\"https:\/\/kyaserv.com.ar\/web\/celdas-de-carga-cardinal\/\" rel=\"nofollow\">M\u00e1s informaci\u00f3n &rarr;<\/a><\/p>\n","protected":false},"author":3,"featured_media":2159,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_joinchat":[]},"categories":[11,65],"tags":[],"jetpack_featured_media_url":"https:\/\/kyaserv.com.ar\/web\/wp-content\/uploads\/2014\/08\/cardinal_featured.jpg","_links":{"self":[{"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/posts\/2151"}],"collection":[{"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/comments?post=2151"}],"version-history":[{"count":6,"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/posts\/2151\/revisions"}],"predecessor-version":[{"id":2171,"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/posts\/2151\/revisions\/2171"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/media\/2159"}],"wp:attachment":[{"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/media?parent=2151"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/categories?post=2151"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kyaserv.com.ar\/web\/wp-json\/wp\/v2\/tags?post=2151"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}